Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 531
Filter
1.
J Craniomaxillofac Surg ; 52(4): 464-468, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38368205

ABSTRACT

To clinically and radiographically evaluate patient-specific titanium meshes via a trans-antral approach for correction of enophthalmos and orbital volume in patients with recent unilateral orbital floor fracture. Seven patients with unilateral orbital floor fractures received patient-specific titanium meshes that were designed based on a mirror-image of the contralateral intact orbit. The patient-specific implants (PSIs) were inserted via a trans-antral approach without endoscopic assistance. The patients were evaluated clinically for signs of diplopia and restricted gaze as well as radiographically for enophthalmos and orbital volume correction. Diplopia was totally resolved in two of the three patients who reported diplopia in the upward gaze. Whereas enophthalmos significantly improved in all but two patients, with a mean value of 0.2229 mm postoperatively compared to 0.9914 mm preoperatively. CT scans showed excellent adaptation of the PSIs to the orbital floor with a mean reduction of the orbital volume from 29.59 cc to 27.21 cc, a mean of 0.6% smaller than the intact orbit. It can be concluded that the proposed PSI can offer good reconstruction of the orbital floor through an isolated intraoral transantral approach with minimal complications. It could of special benefit in extensive orbital floor fractures.


Subject(s)
Dental Implants , Enophthalmos , Orbital Fractures , Humans , Enophthalmos/diagnostic imaging , Enophthalmos/etiology , Enophthalmos/surgery , Diplopia/etiology , Diplopia/surgery , Titanium , Orbital Fractures/complications , Orbital Fractures/diagnostic imaging , Orbital Fractures/surgery , Orbit/diagnostic imaging , Orbit/surgery , Retrospective Studies
2.
J Craniomaxillofac Surg ; 52(4): 532-537, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38368208

ABSTRACT

This study aimed to compare the accuracy of inferomedial orbital fracture restoration using customized orbital implant versus 3D preformed titanium mesh. Patients were divided into two groups. Group 1 underwent surgery with customized orbital implants and intraoperative navigation, while group 2 was treated using 3D preformed titanium meshes with preoperative virtual surgical planning (VSP) and intraoperative navigation. Reconstruction accuracy was assessed by: (1) comparing the postoperative reconstruction mesh position with the preoperative VSP; and (2) measuring the difference between the reconstructed and unaffected orbital volume. Pre- and postoperative diplopia and enophthalmos were also evaluated. Fifty-two patients were enrolled (25 in group 1 vs 27 in group 2). The mean difference between final plate position and ideal digital plan was 0.62 mm (SD = 0.235) in group 1 and 0.69 mm (SD = 0.246) in group 2, with no statistical difference between the groups (p = 0.282). The mean volume differences between the reconstructed and unaffected orbits were 0.95 ml and 1.02 ml in group 1 and group 2, respectively, with no significant difference between the groups (p = 0.860). Overall clinical improvements, as well as complications, were similar. 3D preformed titanium meshes can reconstruct inferomedial fractures with the same accuracy as customized implants. Therefore, in clinical practice, it is recommended to use 3D preformed meshes for this type of fracture due to their excellent results and the potential for reducing time and costs.


Subject(s)
Dental Implants , Enophthalmos , Orbital Fractures , Orbital Implants , Humans , Orbital Fractures/diagnostic imaging , Orbital Fractures/surgery , Orbital Fractures/complications , Orbital Implants/adverse effects , Titanium , Retrospective Studies , Surgical Mesh/adverse effects , Orbit/surgery , Enophthalmos/etiology , Enophthalmos/surgery
3.
J Craniomaxillofac Surg ; 52(3): 334-339, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38341367

ABSTRACT

Isolated orbital floor fractures are more frequent due to low bone thickness (2 mm). The aim of this study was to conduct a retrospective epidemiological analysis on these fractures, investigating demographic variables and fractures' features and their statistical correlation. A total of 120 patients with isolated orbital floor fracture, admitted at the Maxillofacial Surgery Unit of University of Naples Federico II, from 2010 to 2022 were enrolled in the study. Patients were evaluated for age, sex, smoke, comorbidities, post-traumatic clinical manifestation,s and defect side and size. Statistical analysis was conducted using the Pearson regression coefficient (r). The fractures were more frequent in men (male:female 2.2:1) because of road accidents (30% of cases). The average age was 48 years. Enophthalmos, diplopia and ocular motility anomalies were observed in 31%, 23% and 21% of cases, respectively. Statistical analysis revealed that age was related to fracture area; in particular, older patients showed larger fractures (p < 0.001). Interpersonal violence and traffic accidents were related to younger age (p < 0.001). Data analysis revealed that isolated orbital floor fractures are more frequent in young men (<40 years) because of road accidents or interpersonal violence. There is a statistical correlation between fracture area and patient age; in particular, older age corresponds to larger defects.


Subject(s)
Enophthalmos , Orbital Fractures , Humans , Male , Female , Middle Aged , Retrospective Studies , Tomography, X-Ray Computed , Orbit/surgery , Enophthalmos/etiology , Orbital Fractures/surgery , Demography
4.
BMJ Case Rep ; 17(2)2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38350703

ABSTRACT

Craniomaxillofacial trauma is primarily diagnosed and managed by oral and maxillofacial surgeons. Among the cases encountered, midface fractures involving orbital walls are highly prevalent. In these fractures, involvement of the orbital walls, particularly floor of the orbit, can lead to considerable aesthetic and functional limitations. From a maxillofacial perspective, indications for surgical repair of orbital floor encompass marked decrease in ocular motility, fracture affecting more than 50% of surface area, an increase in orbital volume exceeding 18% and enophthalmos greater than 2 mm. In the absence of these discernible signs, surgical intervention is not generally indicated. However, in this case, an early adolescent with a history of midface trauma and minimal orbital floor fracture 8 months earlier presented with progressively delayed onset enophthalmos and hypoglobus closely resembling features of silent sinus syndrome. The enophthalmos and hypoglobus were corrected by placing custom-made non-resorbable high-density polyethylene implant in the orbital floor. Postoperative follow-up demonstrated aesthetically and functionally satisfactory outcomes.


Subject(s)
Enophthalmos , Orbital Fractures , Paranasal Sinus Diseases , Adolescent , Humans , Enophthalmos/diagnosis , Enophthalmos/etiology , Enophthalmos/surgery , Orbit/surgery , Orbital Fractures/diagnosis , Orbital Fractures/diagnostic imaging , Prostheses and Implants , Eye Movements , Paranasal Sinus Diseases/surgery , Retrospective Studies
5.
Ophthalmic Plast Reconstr Surg ; 40(1): 49-54, 2024.
Article in English | MEDLINE | ID: mdl-37581879

ABSTRACT

PURPOSE: To describe the efficacy and persistence of injectable calcium hydroxyapatite (CAHY) to correct orbital volume deficit in postenucleation socket syndrome. METHODS: An observational study was conducted as a clinical review of all patients in the authors' practice who received injectable CAHY placed in the extraconal and intraconal space to increase orbital volume with a 10-year follow up. The amount of CAHY to be injected was defined according to the degree of orbital volume deficit. Patients previously treated with radiotherapy or with a conjunctival fornix insufficient to accommodate the external prosthesis were excluded. All the patients with at least 10 years of follow up were included in the study. RESULTS: Thirty-one postenucleation socket syndrome patients received injectable CAHY for orbital volume augmentation, with a 10-year follow up. The mean amount of preoperative relative enophthalmos measured by Hertel's exophthalmometry was 14.16 ± 2.15. An increase in the mean orbital volume of 3.35 ± 0.91 at 6 months and 2.97 ± 1.35 at 10 years was obtained. The mean follow-up was 219 ± 18 months (range, 184-240). Patients demonstrated clinical and cosmetic improvement that was observed to continue for 10 years. The complications were peribulbar ecchymosis, 2 extrusions of the internal prosthesis, and 2 ptosis. CONCLUSIONS: Injectable CAHY provides safe, simple, repeatable, and cost-effective technique to treat volume deficiency in the enophthalmic orbit in the long term. The volume augmentation obtained with this semipermanent filler demonstrated a lasting effect in the orbit with negligible loss of volume at 10 years.


Subject(s)
Durapatite , Enophthalmos , Humans , Follow-Up Studies , Retrospective Studies , Enophthalmos/diagnosis , Enophthalmos/etiology , Enophthalmos/surgery , Orbit/surgery , Syndrome
7.
J Plast Surg Hand Surg ; 58: 1-7, 2023 May 16.
Article in English | MEDLINE | ID: mdl-37191355

ABSTRACT

BACKGROUND: Malplaced implants in orbital reconstruction may lead to serious complications and necessitate re-intervention. The aim of this study was to describe outcomes, complications and scenarios of re-intervention in a historical case series of orbital fractures treated with free-hand orbital wall reconstruction. The main hypothesis was that early re-interventions are mainly because of malplaced implants in the posterior orbit. METHODS: Retrospective review of 90 patients with facial fractures involving the orbit, reconstructed with radiopaque orbital wall implants, from 2011 to 2016. Data were obtained from medical records and computed tomography images. Recorded parameters were fracture type, ocular injury, ocular motility, diplopia, eye position, complications and re-interventions. Secondary reconstructions because of enophthalmos were volumetrically evaluated. RESULTS: Early complications requiring re-intervention within 1 month were seen in 12 (13%) patients, where all except two were because of malplaced implants. The implant incongruence was without exception found in the posterior orbit. Late complications consisted of four (4%) cases of ectropion and five (5%) cases of entropion that needed corrective surgery. The majority of the patients with eye-lid complications had undergone repeated surgeries. Secondary orbital surgeries were performed in nine (10%) patients. Five of these patients had secondary reconstruction for enophthalmos and associated diplopia. None of these patients became completely free from either enophthalmos or diplopia after the secondary surgery. CONCLUSION: Re-intervention after orbital reconstruction is mainly related to malplaced implants in the posterior orbit. Incomplete results in patients requiring secondary surgery for enophthalmos infer the importance of accurate restoration of the orbit at primary surgery. Abstract presented at: Swedish surgery Week 2021 and SCAPLAS 2022.


Subject(s)
Enophthalmos , Orbital Fractures , Orbital Implants , Humans , Enophthalmos/diagnostic imaging , Enophthalmos/etiology , Enophthalmos/surgery , Orbital Fractures/diagnostic imaging , Orbital Fractures/surgery , Orbital Fractures/complications , Diplopia/etiology , Diplopia/surgery , Orbit/surgery , Orbital Implants/adverse effects , Retrospective Studies , Treatment Outcome
8.
Rhinology ; 61(4): 297-311, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37219052

ABSTRACT

INTRODUCTION: Silent sinus syndrome (SSS) is a rare disorder of the maxillary sinus, which may present with orbital symptoms. Most reports of silent sinus syndrome are limited to small series or case reports. This systematic review comprehensively characterizes the various clinical presentations, management, treatment, and outcomes in patients with SSS. METHODS: A systematic literature search of the PubMed, Cochrane, Web of Science, and Scopus databases. Inclusion criteria were studies describing the presentation, management, or treatment of SSS or chronic maxillary atelectasis. RESULTS: One hundred fifty-three articles were included in the final review (n=558 patients). Mean age at diagnosis was 38.8 +- 14.1 years, with a relatively even distribution among sexes. Enophthalmos and/or hypoglobus were the most frequent symptoms, along with diplopia, headache, or facial pressure/pain. Most patients (87%) underwent functional endoscopic sinus surgery (FESS), and 23.5% received orbital floor reconstruction. Post-treatment, patients had significant reductions in enophthalmos (2.67 +- 1.39 vs. 0.33 +- 0.75 mm) and hypoglobus (2.22 +- 1.43 vs. 0.23 +- 0.62 mm). Most patients (83.2%) achieved partial or total resolution of clinical symptoms. CONCLUSIONS: SSS has a variable clinical presentation, with enophthalmos and hypoglobus being most common. FESS with or without orbital reconstruction are effective treatments to address the underlying pathology and structural deficits.


Subject(s)
Enophthalmos , Paranasal Sinus Diseases , Humans , Young Adult , Adult , Middle Aged , Enophthalmos/diagnosis , Enophthalmos/etiology , Enophthalmos/therapy , Retrospective Studies , Tomography, X-Ray Computed , Syndrome , Paranasal Sinus Diseases/diagnosis , Paranasal Sinus Diseases/surgery , Maxillary Sinus/surgery
9.
J Craniofac Surg ; 34(4): e391-e393, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37101320

ABSTRACT

The present work aims to report 2 clinical cases of the use of current technologies for the treatment of orbital fractures. The cases are of patients who were victims of car accidents and who developed a blow-out orbital fracture. Clinically, they presented periorbital ecchymosis, blepharoedema, enophthalmos, and ophthalmoplegia and, therefore, underwent surgical reconstructive treatment. For both cases, preoperative computed tomography and biomodel impression of the orbits were performed. The modeling of the titanium mesh covering the defect in the biomodel that would be used in the surgery was performed. In the intraoperative period of reduction and fixation of the fracture with the titanium mesh, optics were used to better visualize the posterior defect, as well as computed tomography to ensure that the entire affected area was reconstructed. Both patients were followed up in the postoperative period and evolved without clinical and functional complaints.


Subject(s)
Orbit , Orbital Fractures , Orbital Fractures/diagnostic imaging , Orbital Fractures/surgery , Humans , Tomography, Optical , Ecchymosis/etiology , Enophthalmos/etiology , Ophthalmoplegia/etiology , Orbit/diagnostic imaging , Tomography, X-Ray Computed , Surgical Mesh , Titanium , Treatment Outcome
10.
J Craniofac Surg ; 34(5): 1420-1426, 2023.
Article in English | MEDLINE | ID: mdl-37101317

ABSTRACT

PURPOSE: Orbital volume increase has been previously linked with post-traumatic enophthalmos. However, this varies and some studies show no correlation. This systematic review and meta-analysis aimed to synthesize the correlation between orbital volume and enophthalmos and to determine if surgical intervention, enophthalmos measurement method, fracture location, or timing affect this correlation. METHODS: Automation tools were used to assist in this review of 6 databases. Searches were performed across all dates. Included studies quantitatively reported orbital volume and enophthalmos following traumatic orbital wall fractures in at least 5 adult subjects. Correlational data were extracted or calculated. Random-effects meta-analysis was used with subgroup analyses for each of the secondary aims. RESULTS: Twenty-five articles describing 648 patients were included. The pooled correlation between orbital volume and enophthalmos was r =0.71 ( R2 =0.50, P <0.001). Operative status, enophthalmos measurement method, and fracture location did not affect pooled correlation. The delay between trauma or surgery and enophthalmos measurement was not shown to modulate correlation for unoperated patients ( R2 =0.05, P =0.22) but showed a negative relationship for postoperative patients ( z =-0.0281, SE=0.0128, R2 =0.63, P =0.03), but this was heavily influenced by a single article. All results had high residual heterogeneity. Studies were rated as moderate, low, or very low quality with few stating explicit hypotheses or limitations. CONCLUSIONS: Bony orbital volume expansion accounts for around 50% of post-traumatic enophthalmos. The other half is probably explained by soft tissue or geometric bony, rather than volumetric, changes.


Subject(s)
Enophthalmos , Eye Injuries , Orbital Fractures , Adult , Humans , Enophthalmos/etiology , Enophthalmos/complications , Orbital Fractures/complications , Orbital Fractures/diagnostic imaging , Orbital Fractures/surgery , Eye Injuries/complications , Automation , Orbit/surgery , Retrospective Studies
12.
Technol Health Care ; 31(5): 1647-1657, 2023.
Article in English | MEDLINE | ID: mdl-36970917

ABSTRACT

BACKGROUND: Orbital blowout fracture is common in ocular trauma. Accurate measurement of orbital volume after fracture is key in improving intraocular correction. OBJECTIVE: This study aims to explore the impact of 3D reconstruction technology in restoring normal exophthalmos in patients with old orbital wall fractures. METHODS: A total of 31 patients were randomly divided into an experimental group (n= 15) and a control group (n= 16). For orbital wall repair and reconstruction, the conventional group used the conventional surgical scheme, and the 3D group used 3D printing technology. RESULTS: There was no statistical difference between the preoperative mean extraocular muscle volume of the healthy eye and the affected eye. However, the mean orbital volume (24.76 vs 27.11, P= 0.005) and mean retrobulbar fat volume (17.53 vs 16.42, P= 0.006) were significantly different between the healthy eye and the affected eye. After an average follow-up of 16 weeks, the differences in pre- and post-surgery exophthalmos in the two groups were 0.42 ± 0.08 mm and 1.63 ± 0.51 mm, respectively. The difference between the two groups was statistically significant (t= 4.42, P= 0.003). The complications were not statistically different. CONCLUSION: Using 3D reconstruction technology preoperatively can significantly improve exophthalmos in patients with old orbital wall fractures.


Subject(s)
Enophthalmos , Exophthalmos , Orbital Fractures , Plastic Surgery Procedures , Humans , Enophthalmos/etiology , Enophthalmos/surgery , Imaging, Three-Dimensional , Exophthalmos/surgery , Exophthalmos/complications , Orbital Fractures/complications , Orbital Fractures/surgery , Retrospective Studies
13.
J Craniofac Surg ; 34(5): e449-e451, 2023.
Article in English | MEDLINE | ID: mdl-36935393

ABSTRACT

BACKGROUND: The use of an acellular dermal matrix is rarely reported in orbital wall fracture reconstruction. This study aimed to share the author's experience with the cross-linked acellular dermal matrix as an allograft material for enophthalmos correction. METHODS: In this retrospective study, the author evaluated the medical records and 3-dimensional facial computed tomography scans of patients with enophthalmos caused by neglected orbital fractures between May 2021 and June 2022. Facial computed tomography scans confirmed the clinical diagnosis of enophthalmos. A single surgeon performed all surgical operations. In all patients, the author accessed the orbital floor via subciliary incision while approaching the medial wall with a retrocaruncular incision. After fully exposing the lesion, the author used a 1.0-mm-thick cross-linked acellular dermal matrix (ADM) (MegaDerm; L&C Bio, South Korea). After trimming the cross-linked ADM to a proper size, the author implanted the ADM into the lesion. RESULTS: During May 2021 and June 2022, 3 cases of enophthalmos were successfully corrected with cross-linked ADM at the author's hospital. All patients were improved clinically and radiologically. CONCLUSION: This is the first study to show the effectiveness of cross-linked ADM for the correction of enophthalmos.


Subject(s)
Acellular Dermis , Enophthalmos , Orbital Fractures , Plastic Surgery Procedures , Humans , Enophthalmos/diagnostic imaging , Enophthalmos/etiology , Enophthalmos/surgery , Retrospective Studies , Orbit/surgery , Orbital Fractures/complications , Orbital Fractures/diagnostic imaging , Orbital Fractures/surgery
14.
Ophthalmic Plast Reconstr Surg ; 39(5): 487-491, 2023.
Article in English | MEDLINE | ID: mdl-36972118

ABSTRACT

PURPOSE: Determining the hemodynamic characteristics of an orbital vascular malformation is a critical step in management. The purpose of this study is to assess the relationship between enophthalmos and clinically apparent distensibility of orbital vascular malformations, to optimize imaging and treatment. METHODS: In this cross-sectional cohort study consecutive patients at a single institution were screened for study entry. Data extracted included age, sex, Hertel measurements, presence or absence of distensibility during the Valsalva maneuver, whether lesions were primarily venous or lymphatic based on imaging, and location of the lesion relative to the globe. Enophthalmos was defined as ≥ 2 mm difference from the opposite side. Parametric and nonparametric statistics were used, and linear regression was performed to examine factors predictive of Hertel measurement. RESULTS: Twenty-nine patients met the inclusion criteria. Relative enophthalmos ≥2 mm was significantly associated with distensibility ( p = 0.03; odds ratio = 5.33). Distensibility and venous dominant morphology were the 2 most important factors associated with enophthalmos on regression analysis. The relative position of the lesion anterior or posterior to the globe did not have a significant bearing on baseline enophthalmos. CONCLUSIONS: The presence of enophthalmos increases the likelihood that an orbital vascular malformation is distensible. This group of patients was also more likely to be characterized by venous dominant malformations. Baseline clinical enophthalmos may serve as a useful surrogate marker for distensibility and venous dominance, which may be useful in guiding the selection of appropriate imaging.


Subject(s)
Enophthalmos , Orbital Diseases , Orbital Fractures , Vascular Malformations , Humans , Enophthalmos/diagnosis , Enophthalmos/etiology , Orbit/pathology , Cross-Sectional Studies , Orbital Diseases/pathology , Vascular Malformations/complications , Vascular Malformations/diagnosis , Vascular Malformations/pathology , Orbital Fractures/pathology
15.
Otolaryngol Head Neck Surg ; 169(1): 151-156, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36939460

ABSTRACT

OBJECTIVE: The term "silent sinus syndrome" (SSS) describes spontaneous enophthalmos secondary to subclinical maxillary sinus atelectasis. Debate remains on whether treatment with endoscopic maxillary antrostomy alone is adequate in reversing atelectasis and globe displacement. This study aims to determine the degree of volume change of the diseased sinus and orbit as well as the change in orbital height in patients treated with endoscopic antrostomy without orbital floor augmentation. STUDY DESIGN: Retrospective review with image analysis. SETTING: Single tertiary care institution. METHODS: Three-dimensional (3D) analysis of computed tomographic imaging data was performed using 3D Slicer. 3D models of the maxillary sinus and orbit of the diseased and normal sides were created, and volume measurements were calculated using the segmentation program. RESULTS: Thirteen patients with SSS who underwent endoscopic sinus surgery (ESS) and had follow-up computed tomographic imaging were analyzed. After endoscopic antrostomy, the mean volume of the diseased maxillary sinus significantly increased by 9.82%, from 6.37 to 7.00 cm3 (p = .0302). There was no significant change in mean orbital volume; however, the mean orbital height decreased by 5.67%, from 38.09 to 35.93 mm from pretreatment to posttreatment samples (p = .0101). All patients had resolution of clinical or radiographic enophthalmos and orbital displacement with ESS alone. CONCLUSION: Endoscopic maxillary antrostomy alone in the treatment of SSS significantly increased maxillary sinus volume and decreased diseased orbital height. These changes were associated with clinical and radiographic improvement in globe displacement. These findings support performing ESS alone, reserving orbital augmentation for patients who do not exhibit adequate clinical improvement.


Subject(s)
Enophthalmos , Paranasal Sinus Diseases , Pulmonary Atelectasis , Humans , Orbit/diagnostic imaging , Orbit/surgery , Enophthalmos/diagnostic imaging , Enophthalmos/etiology , Enophthalmos/surgery , Maxillary Sinus/diagnostic imaging , Maxillary Sinus/surgery , Paranasal Sinus Diseases/diagnostic imaging , Paranasal Sinus Diseases/surgery
16.
Plast Reconstr Surg ; 152(6): 1313-1318, 2023 12 01.
Article in English | MEDLINE | ID: mdl-36940154

ABSTRACT

SUMMARY: Long-term enophthalmos is a common orbital fracture sequela. Various autografts and alloplastic materials have been studied in posttraumatic enophthalmos repair. However, expanded polytetrafluoroethylene (ePTFE) implantation in late enophthalmos repair has rarely been reported. The authors report novel use of ePTFE for late posttraumatic enophthalmos repair. This retrospective study included patients with posttraumatic long-term enophthalmos who underwent hand-carved ePTFE intraorbital implantation for enophthalmos correction. Computed tomography data were collected preoperatively and at follow-up. The volume of ePTFE, the degree of proptosis (DP), and enophthalmos were measured. Postoperative and preoperative DP and enophthalmos were compared using the paired t test. The correlation between ePTFE volume and DP increment was established using linear regression. Complications were identified by chart review. From 2014 to 2021, 32 patients were included, with a mean follow-up of 19.59 months. The mean volume of implanted ePTFE was 2.39 ± 0.89 mL. After surgery, the DP of the affected globe improved significantly, from 12.75 ± 2.12 mm to 15.06 ± 2.50 mm ( P < 0.0001). A significant linear correlation was found between ePTFE volume and DP increment ( P < 0.0001). Enophthalmos was substantially ameliorated from 3.35 ± 1.89 mm to 1.09 ± 2.07 mm ( P < 0.0001). Twenty-five patients (78.23%) had postoperative enophthalmos of less than 2 mm. Infection and implant dislocation were not observed. The authors concluded that ePTFE intraorbital implantation exhibited long-term efficacy and safety for late posttraumatic enophthalmos repair and represents an effective and predictable alternative. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.


Subject(s)
Enophthalmos , Orbital Fractures , Humans , Enophthalmos/etiology , Enophthalmos/surgery , Polytetrafluoroethylene , Retrospective Studies , Prostheses and Implants/adverse effects , Tomography, X-Ray Computed/adverse effects , Orbital Fractures/complications , Orbital Fractures/surgery , Treatment Outcome
17.
Plast Reconstr Surg ; 152(3): 629-637, 2023 09 01.
Article in English | MEDLINE | ID: mdl-36780363

ABSTRACT

BACKGROUND: Orbital floor fracture defect size and inferior rectus (IR) rounding index are currently accepted indications for surgery to prevent late enophthalmos. The authors analyzed the positive predictive value (PPV) of these indications. METHODS: Twenty-eight patients with orbital floor fractures presenting without enophthalmos underwent Hertel exophthalmometry at presentation and at weeks 1, 2, 3, 6, 13, 26, and 52 or more after injury. Orbital defect size and IR rounding index were measured from computed tomographic scans, and PPVs of defects of 1.5 to 2 cm 2 or larger and IR rounding index of 1 or higher for enophthalmos (≥2 mm) were calculated. RESULTS: Nineteen patients had isolated orbital floor fractures (group A), three had noncontinuous orbital floor and medial wall fractures (group B), and six had continuous orbital floor with medial wall fractures (group C). Mean follow-up time was 440 days. Of all patients, 20 had a defect size of 1.5 cm 2 or larger, 12 had a defect of 2.0 cm 2 or larger, and 13 had an IR rounding index of 1 or higher. Of the 28 patients, only one from group A and two from group C developed enophthalmos of 2 mm only. The PPVs of orbital floor defect size of 1.5 cm 2 or larger and 2 cm 2 or larger (groups A and B only) for late enophthalmos were 6.7% and 0%, respectively. The PPV of IR rounding index of 1 or higher for late enophthalmos (all groups) was 0%. CONCLUSIONS: For patients with orbital floor fractures presenting without enophthalmos, defects of 1.5 cm 2 or larger and 2 cm 2 or larger, and IR rounding index of 1 or higher, are weakly predictive of late enophthalmos. Furthermore, patients who do not develop enophthalmos within 3 weeks of injury are unlikely to develop significant (>2 mm) late enophthalmos. CLINICAL QUESTION/LEVEL OF EVIDENCE: Risk, III.


Subject(s)
Enophthalmos , Fractures, Multiple , Orbital Fractures , Humans , Enophthalmos/etiology , Enophthalmos/surgery , Orbit/diagnostic imaging , Orbit/surgery , Oculomotor Muscles , Tomography, X-Ray Computed/methods , Orbital Fractures/complications , Orbital Fractures/diagnostic imaging , Orbital Fractures/surgery , Retrospective Studies
18.
Semin Ophthalmol ; 38(4): 365-370, 2023 May.
Article in English | MEDLINE | ID: mdl-36639878

ABSTRACT

PURPOSE: To compare the outcome of orbital blowout fracture repair by means of pre-formed porous-polyethylene titanium implants (PFI) vs patient-specific porous-polyethylene implants (PSI). METHODS: Retrospective cohort study. Baseline characteristics, ophthalmic examination results, ocular motility, fracture type, the timing of surgery, implant type, and final relative enophthalmos of all patients operated on for blow-out fractures in a single center were collected and analyzed. RESULTS: Twenty-seven patients (mean age 39 years, 9 females) were enrolled. Sixteen underwent fracture repair with PFI and 11 with PSI at 11 months (median) post-trauma. Mean follow-up duration was 1.1 years. Both groups showed significant postoperative improvement in primary or vertical gaze diplopia (P = .03, χ2). Relative enophthalmos improved from -3.2 preoperative PFI to -1.7 mm postoperative PFI, and from -3.0 mm preoperative PSI to -1.1 mm postoperative PSI (P= .1). PSI patients had non-significantly less postoperative enophthalmos and globe asymmetry than PFI patients. The outcome was not influenced by previous surgery, age, sex, number of orbital walls involved in the initial trauma, or medial wall involvement (linear regression). Both groups sustained complications unrelated to implant choice. CONCLUSION: Both PSI and PFI yielded good outcomes in this study. PSI may be a good alternative to PFI in primary or secondary orbital blowout fracture repair with less enophthalmos and globe asymmetry, in spite of the possible disadvantages of production time, a relatively larger design, and challenging insertion. Since it is a mirror image of the uninjured orbit, it may be beneficial in extensive fractures.


Subject(s)
Enophthalmos , Orbital Fractures , Orbital Implants , Plastic Surgery Procedures , Female , Humans , Adult , Enophthalmos/etiology , Enophthalmos/surgery , Orbital Implants/adverse effects , Retrospective Studies , Orbit/surgery , Polyethylene , Orbital Fractures/surgery , Orbital Fractures/complications
19.
J Plast Reconstr Aesthet Surg ; 77: 104-110, 2023 02.
Article in English | MEDLINE | ID: mdl-36563635

ABSTRACT

The application of navigation and endoscope is an area of intense interest in the surgical repair of orbital fractures. This study explored the advantages of a combined endoscopy navigation technique (ENT) for repairing large orbital floor and medial wall fractures (OFMWFs) with destruction of the inferomedial strut (IMS). Fifty-two consecutive patients with large OFMWFs with the destruction of the IMS underwent ENT-assisted surgical repair from January 2013 to February 2016. Patient demographics, causes of injury, clinical features, imaging data, and follow-up information (diplopia, ocular dysmotility, enophthalmos, infraorbital hypoesthesia, and other conditions) were collected and analyzed. Orbital volumes and implant positions were also evaluated. The median follow-up duration was 21 (range, 16-29) months. At the end of the follow-up visits, orbital reconstruction was demonstrated by orbital computed tomography. Of the 30 patients with diplopia within the 30-degree visual field of gaze, 27 (90%) reached diplopia remission. Of 40 patients, 34 (85%) achieved complete elimination of ocular dysmotility. Of 47 patients with enophthalmos of >2 mm, 43 (91%) acquired good symmetry with a mean improvement of 3.00 ± 1.00 mm. Of 33 patients, 27 (82%) recovered from infraorbital hypoesthesia. The postoperative orbital volumes of the two sides showed no significant differences (p = 0.087, paired t-test). Early surgical repair showed better outcomes of diplopia, ocular motility, and enophthalmos than late repair (p = 0.001, p = 0.007, and p = 0.000, generalized estimated equations). No patient developed surgery-related complications of visual acuity compromise, strabismus, ectropion, entropion, or lacrimal canaliculus injuries. ENT-assisted surgery appears to be safe, precise, and effective for the repair of large OFMWFs with destruction of the IMS.


Subject(s)
Enophthalmos , Orbital Fractures , Humans , Orbital Fractures/diagnostic imaging , Orbital Fractures/surgery , Orbital Fractures/complications , Enophthalmos/etiology , Enophthalmos/surgery , Diplopia/etiology , Hypesthesia/complications , Endoscopy/methods , Retrospective Studies , Treatment Outcome
20.
Can J Ophthalmol ; 58(2): 113-117, 2023 04.
Article in English | MEDLINE | ID: mdl-34715034

ABSTRACT

OBJECTIVE: Silent sinus syndrome (SSS) usually manifests clinically as hypoglobus and enophthalmos. Patients may experience different symptoms and may present to an assortment of specialties and delay diagnosis and management. The objective of this article was to describe the different and sometimes misleading signs and symptoms of SSS to improve the level of suspicion and reduce time to diagnosis. METHODS: A retrospective consecutive audit of the records of all patients diagnosed with SSS between 2015 and 2019 in the Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust. Demographic and clinical data including presentation, diagnosis, and symptoms were obtained from the patients' medical files. RESULTS: Ten patients were included; mean age was 42.5 ± 11.5 years (range, 16-56 years). Four patients were initially referred to an ophthalmologist with globe asymmetry, diplopia, eyelid asymmetry, or retraction. Three patients were initially referred to an ear, nose, and throat specialist with facial asymmetry or infraorbital paraesthesia. Two patients were referred from the maxillofacial department with an incidental finding, and the last patient was seen initially by the neurology team with headaches. CONCLUSION: SSS has a variable presentation. Patients may have common or misleading signs. Patients may attend different clinics and subspecialties, and physicians should be aware of the broad range of presenting signs in this condition to prevent delay in diagnosis and further morbidity.


Subject(s)
Enophthalmos , Paranasal Sinus Diseases , Humans , Adult , Middle Aged , Retrospective Studies , Tomography, X-Ray Computed , Syndrome , Maxillary Sinus , Enophthalmos/diagnosis , Enophthalmos/etiology , Paranasal Sinus Diseases/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...